Lynxspring JENEsys Edge Installation & Programming

Niagara 4 all the way down to the equipment. We install, program, and service Lynxspring JENEsys Edge controllers on air handlers, rooftop units, VAV boxes, central plants, and packaged equipment.

JENEsys EdgeNiagara 4Onyxx XM I/OPC-9000BACnet / Modbus

Lynxspring, based in Lee's Summit, Missouri, builds JENEsys Edge controllers that put a full Niagara 4 station on Lynxspring's Onyxx hardware, right at the equipment. The controller on an air handler is engineered in the same Niagara Workbench, with the same wiresheet logic, Fox connection, and BACnet and Modbus drivers, as the supervisor above it. The family scales by I/O and licensing: the Edge 414 and 514 with 14 built-in I/O, the 434 and 534 with 34, the newer Edge 634 licensed for network-area management, and an Edge VAV with Guideline 36 sequences. The 514, 534, and 634 expand with Onyxx XM I/O modules, and the PC-9000 serves as Lynxspring's JACE-class Niagara 4 controller. For a Niagara-first contractor like Vertex, it's a natural fit: one toolset, one programming standard, and controllers any certified Niagara integrator can maintain.

WHAT WE DO ON LYNXSPRING

New JENEsys Edge installs

Panel design and build, controller and Onyxx I/O sizing, installation, and wiring for new equipment or controls retrofits. We match the Edge model and license to the points list instead of over-buying.

Niagara 4 programming at the controller

Sequences written in Niagara wiresheets to the same standard as our supervisor work: consistent point naming, reusable logic, and a documented sequence of operations.

Integration into your front end

Edge controllers joined to a Niagara supervisor over Fox, or to a third-party BAS over BACnet, with alarms, trends, and graphics set up end to end.

Service, backups, and upgrades

Troubleshooting, Niagara version upgrades, license changes, and station backups for JENEsys controllers we installed or inherited.

LYNXSPRING PRODUCT LINES WE WORK WITH

  • JENEsys Edge 414 and 434
    Niagara 4 controllers for smaller equipment and price-sensitive projects, with 14 and 34 built-in I/O.
  • JENEsys Edge 514 and 534
    Fully programmable Niagara 4 controllers with 14 and 34 built-in I/O, expandable with Onyxx XM I/O up to 306 points.
  • JENEsys Edge 634
    Lynxspring's newest Edge controller, with 34 I/O and licensing up to 5,000 points and 100 devices for network-area management.
  • JENEsys Edge VAV
    VAV controller with a built-in differential pressure transducer and ASHRAE Guideline 36 sequences.
  • JENEsys PC-9000 and N4 Supervisor
    Lynxspring's JACE-class Niagara 4 controller and its Niagara 4 supervisor software.
  • Onyxx XM I/O
    14- and 34-point I/O extenders, including a BACnet MS/TP version, that add points without adding another controller.

TYPICAL PROJECTS

Air handler and rooftop unit controls

Edge controllers mounted at the unit, programmed for Guideline 36-style sequences, and joined to the building's Niagara supervisor.

Central plant control

Chiller, boiler, and pump sequencing on an Edge 534 or 634 with Onyxx XM I/O expansion, trended and alarmed at the supervisor.

VAV zones on Niagara

JENEsys Edge VAV controllers running Guideline 36 zone sequences, programmed in the same Workbench as the rest of the building.

Packaged and OEM equipment

Standardized Niagara programs built once and reused on every unit of the same type across a portfolio.

FAQ

Lynxspring questions we hear

What is a JENEsys Edge controller?
A Lynxspring controller that runs Tridium Niagara 4 on Lynxspring's Onyxx hardware. It is programmed in Niagara Workbench like any Niagara station, communicates over Fox, BACnet, and Modbus, and can run equipment on its own or under a Niagara supervisor.
Which JENEsys Edge model do we need?
It depends on point count and integration. The 414 and 434 suit smaller equipment, the 514 and 534 are fully programmable and expand with Onyxx XM I/O, the 634 adds licensing for network-area management, and the Edge VAV is built for VAV boxes. We size the model and license from your points list.
Can JENEsys Edge controllers join our existing Niagara system?
Yes. They are Niagara 4 stations, and Lynxspring ships JENEsys products with open Niagara compatibility, so they connect to a Niagara supervisor over Fox and to other building automation systems over BACnet.
Do you install Lynxspring controllers on retrofits as well as new construction?
Both. We design and build panels, install and wire controllers and I/O, program and commission the sequences, and hand over documentation and station backups.
Do you work on Lynxspring systems outside Louisiana?
Yes. We are on-site across Louisiana, travel nationwide for Lynxspring installation and commissioning work, and support systems remotely in all 50 states over secure VPN.