Honeywell Niagara Controls Installation, Programming & Service

Honeywell owns Niagara, and its current controls run on it. We install, program, and service Honeywell Optimizer controllers, WEBs-N4 supervisors, and CIPer and Spyder controllers, and bring older Excel 5000 sites onto Niagara.

Niagara 4OptimizerWEBs-N4SpyderCIPer

Honeywell owns Tridium, the company behind the Niagara Framework, and its current building controls are built on it. The Optimizer Suite covers Niagara-based plant and integration controllers, unitary and VAV controllers, and the Optimizer Supervisor; WEBs-N4 supervisors run on WEB-8000 controllers and servers; CIPer controllers are Niagara-based IP controllers; and Spyder controllers are programmed from WEBStation-N4, Honeywell's Niagara Workbench. A Honeywell building is engineered with the same tools, drivers, and standards as the rest of a Niagara portfolio, and it brings in other brands over BACnet. Vertex installs new Honeywell Niagara systems, expands existing ones, programs sequences and graphics, and brings older Excel 5000 sites onto Niagara in phases.

WHAT WE DO ON HONEYWELL

New Optimizer and WEBs-N4 installs

Engineering, panel build, installation, and wiring of Optimizer, WEB-8000, CIPer, and Spyder controllers and field devices for new construction, additions, and retrofits.

Niagara programming and graphics

Controller logic, Spyder applications, graphics, schedules, trends, and alarms in WEBStation-N4 and Niagara 4, built to one documented standard.

Expansions and integration

New equipment added to existing Honeywell systems, and other brands in the building brought into the same Niagara front end over BACnet.

Excel 5000 upgrades onto Niagara

Excel 5000 sites moved in phases: Honeywell's C-Bus integration module puts the existing XL5000 controllers under a Niagara supervisor first, and controllers are replaced as they fail or as budget allows.

HONEYWELL PRODUCT LINES WE WORK WITH

  • Optimizer Suite
    Honeywell's current Niagara-based line: Optimizer Advanced and Essential plant controllers, Optimizer Unitary and VAV controllers, and Optimizer Supervisor.
  • WEBs-N4 and WEB-8000
    Honeywell's Niagara 4 supervisor software and the WEB-8000 controllers it runs on.
  • CIPer Model 30 and 50
    Niagara-based IP controllers for plant and equipment control.
  • Spyder controllers
    Programmable VAV and unitary controllers, including Spyder Model 5 and Model 7, configured with the Spyder Tool in WEBStation-N4.
  • Excel 5000 (legacy)
    Honeywell's earlier C-Bus based family, still running in many buildings and bridged to Niagara with Honeywell's C-Bus integration module.

TYPICAL PROJECTS

Excel 5000 upgrades

XL5000 controllers bridged to a Niagara supervisor through the C-Bus integration module, then replaced in phases with Optimizer or Spyder controllers.

New construction and additions

Optimizer or WEB-8000 supervisors with Optimizer, CIPer, and Spyder controllers, installed and programmed for new buildings, wings, and tenant fit-outs.

Rooftop unit, AHU, and VAV controls

Optimizer Unitary and VAV or Spyder controllers on packaged units, air handlers, and VAV boxes, integrated into the Niagara front end.

Mixed-vendor sites

Honeywell systems and other brands brought together under one Niagara 4 front end.

FAQ

Honeywell questions we hear

Is Honeywell's system the same as Niagara?
Honeywell's current controls are built on Niagara 4. WEBs-N4 and Optimizer Supervisor are Honeywell's Niagara 4 supervisors, WEBStation-N4 is its branded Niagara Workbench, and Optimizer and CIPer controllers run Niagara, so Niagara-certified technicians engineer and service them with the same tools.
Do you install new Honeywell systems or only service existing ones?
Both. We install new Optimizer, WEBs-N4, CIPer, and Spyder systems, expand existing Honeywell sites, and service and upgrade older Excel 5000 systems.
Can you upgrade our Excel 5000 system?
Yes, in phases. Honeywell's C-Bus integration module brings existing XL5000 controllers under a Niagara supervisor without replacing them, so the front end moves first and controllers are replaced as they fail or as budget allows, reusing wiring and field devices that are still sound.
Do you program Spyder controllers?
Yes. We program Spyder applications for VAV boxes, rooftop units, air handlers, and unitary equipment with the Spyder Tool in WEBStation-N4 and integrate them into the building's Niagara front end.
Do you work on Honeywell systems outside Louisiana?
Yes. We are on-site across Louisiana, travel nationwide for Honeywell installation and commissioning work, and support systems remotely in all 50 states over secure VPN.

Honeywell, Optimizer, WEBs, WEBStation, CIPer, Spyder, Excel 5000, and Niagara are trademarks of their respective owners.

Have a Honeywell project?

New Honeywell installs, expansions, programming, and service. Tell us about the building and we'll send a clear scope and an honest price.